{"created":"2023-05-18T09:54:49.217896+00:00","id":112,"links":{},"metadata":{"_buckets":{"deposit":"ba7234b9-a1dc-4b55-9319-a6a94c2f5e47"},"_deposit":{"created_by":2,"id":"112","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"112"},"status":"published"},"_oai":{"id":"oai:jwcpe.repo.nii.ac.jp:00000112","sets":["6:7:34"]},"author_link":["1149","1150","1153","1154","1151","1152"],"control_number":"112","item_3_biblio_info_8":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-03","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"14","bibliographicPageStart":"9","bibliographicVolumeNumber":"27","bibliographic_titles":[{"bibliographic_title":"日本女子体育大学体育学部附属基礎体力研究所紀要"},{"bibliographic_title":"Journal of exercise science","bibliographic_titleLang":"en"}]}]},"item_3_description_42":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"Bulletin","subitem_description_type":"Other"}]},"item_3_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The aim of this study was to evaluate correspondence between saturation of arterial\nblood oxygen measured invasively (SaO2) and saturation of arterial blood oxygen measured\nnon-invasively by pulse oximeter (SpO2) under hypoxic and normobaric environments.\nSeven young adult females were exposed to three graded hypoxic conditions\nwith an interval of normobaric condition. The hypoxic condition was made by the\nequipment of portable altitude simulator (AltoLab ELITE Kit, AltoLab USA) which provides\nhypoxic environments simulating high altitude conditions of 1500 m, 3000 m,\nand 4500 m. Partial pressure of arterial blood oxygen (PaO2), carbon-dioxide (PaCO2),\nand SaO2 were measured in a spot during normobaric and hypoxic conditions, while\nSpO2 was continuously monitored by a pulse oximeter through experiments. From the\nnormobaric environment to the sever hypoxic condition equivalent to 4500 m altitude,\nPaO2 decreased significantly from 91.5+/- 3.5 mmHg to 43.0+/- 6.1 mmHg despite stable\nPaCO2 from 39.4+/- 3.8 mmHg to 41.5+/- 4.9 mmHg, suggesting that the device of\nhypoxic simulator was able to produce a relevant hypoxic condition in arterial blood.\nContinuously collected data of SpO2 measured by pulse oximeter were significantly decreased\n89.0+/- 2.9% (1500 m), 75.3+/- 5.4% (3000 m), and 73.7+/- 4.7% (4500 m).\nAfter 6 minutes of each hypoxic training, SpO2 were recovered during 4 minutes of rest\n(0 m). In addition, SpO2 at the altitude of 4500 m was almost identical to 75.3+/- 5.6%\nmeasured in SaO2. These results suggest that SpO2 reflects accurately SaO2 even under\nsevere hypoxic condition and, therefore, portable pulse oximeter is useful to medical\nevaluation of arterial oxygenation in hypoxic environment.","subitem_description_type":"Abstract"}]},"item_3_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.34349/00000106","subitem_identifier_reg_type":"JaLC"}]},"item_3_publisher_35":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本女子体育大学"}]},"item_3_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10428872","subitem_source_identifier_type":"NCID"}]},"item_3_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"09183825","subitem_source_identifier_type":"ISSN"}]},"item_3_textarea_4":{"attribute_name":"著者所属","attribute_value_mlt":[{"subitem_textarea_value":"日本女子体育大学"},{"subitem_textarea_value":"日本女子体育大学"}]},"item_3_version_type_18":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"夏井, 裕明"}],"nameIdentifiers":[{"nameIdentifier":"1149","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"井筒, 紫乃"}],"nameIdentifiers":[{"nameIdentifier":"1150","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Natsui, Hiroaki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1153","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Izutsu, Shino","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1154","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2019-08-21"}],"displaytype":"detail","filename":"nichijo_jes_kiyo27-02.pdf","filesize":[{"value":"863.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"nichijo_jes_kiyo27-02.pdf","url":"https://jwcpe.repo.nii.ac.jp/record/112/files/nichijo_jes_kiyo27-02.pdf"},"version_id":"748e49c0-26d1-4ffc-b46b-6e2463b1a0ae"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Pulse Oximeter","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"PaO2","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"SaO2","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"SpO2","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"High altitude","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"低酸素環境下における動脈血酸素飽和度(SaO2)とパルスオキシメータで計測された経皮的酸素飽和度(SpO2)との対応性に関する研究","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"低酸素環境下における動脈血酸素飽和度(SaO2)とパルスオキシメータで計測された経皮的酸素飽和度(SpO2)との対応性に関する研究","subitem_title_language":"ja"},{"subitem_title":"A Study of Correspondence between Saturation of Arterial Blood Oxygen and Peripheral Oxygen Saturation Measured by Pulse Oximeter in Hypoxic Environment","subitem_title_language":"en"}]},"item_type_id":"3","owner":"2","path":["34"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2018-06-18"},"publish_date":"2018-06-18","publish_status":"0","recid":"112","relation_version_is_last":true,"title":["低酸素環境下における動脈血酸素飽和度(SaO2)とパルスオキシメータで計測された経皮的酸素飽和度(SpO2)との対応性に関する研究"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2025-04-25T06:59:12.433308+00:00"}